Capable of time-frequency signal measurement and calibration functions
Can perform automatic or timed measurements, and generate test reports and curves
Equipped with a frequency purifier to improve the accuracy of the reference standard
Simultaneous measurement of multiple signals
Data is saved in real-time as needed
Product Features | Specification name | Indicator parameters | Remarkss |
RF Input | Frequency | 1MHz~30MHz | |
Number of simultaneous channels | 4-Channel | Can be increased | |
Frequency accuracy measurement uncertainty | 2E-14 | ||
Frequency stability measurement uncertainty | ≤ 2.0E-14/1s; ≤ 4.0E-15/10s; ≤ 6.0E-16/100s; ≤ 1.0E-16/1000s | ||
Phase noise (10MHz) | 1Hz ≤ -130dBc/Hz 10Hz ≤ -150dBc/Hz 100Hz ≤ -160dBc/Hz 1kHz ≤ -165dBc/Hz 10kHz ≤ -170dBc/Hz | Optional | |
Frequency reproducibility | ---- | ||
aging | ---- | ||
power | -100~30dBm | Optional | |
harmonic | -60dBc | Optional | |
Spurious | -80dBc | Optional | |
Time measurement | Channels | Route 10 | Can be increased |
Pulse measurement range | 0.1ns~10000s | ||
Pulse measurement uncertainty | 0.1ns | ||
Pulse measurement resolution | 0.05ns | ||
IRIG_B(DC) measurement uncertainty | 5us | ||
IRIG_B(AC) measurement uncertainty | 1us | ||
NTP measurement uncertainty | 10us | ||
PTP measurement uncertainty | 10ns | ||
TOD measurement accuracy | 1s | ||
1PPS measurement accuracy | 0.05ns | ||
Monitoring and Control | Condition Monitoring | Measurement log | |
Communication monitoring | RS232, 115200 baud rate RJ45 network port | ||
Supply voltage | Input voltage | 220VAC | |
Power | ≤200W (25℃) | ||
Power supply interface | 220VAC international plug | ||
environment | Operating temperature | -20 ºC ~ +50 ºC | |
Storage temperature | -40 ºC ~ +90 ºC | ||
Relative humidity | 90% non-condensing | ||
Weight and Size | Weight | <100kg | |
Size | Cabinet |