186-1177-6749
Home > Product > Measurement and Calibration Products
ST100 Series Time-Frequency Synthesizer Test Instrument
ST100 Series Time-Frequency Synthesizer Test Instrument
  The ST100 series time-frequency synthesizer test instrument is a professional device that integrates a variety of time and frequency function indicator tests in one. The device is controlled by a touch screen, which is characterized by its convenient operation and compact size. It integrates various time-frequency test functions such as frequency testing, time code measurement, clock analysis, network measurement, and high-precision remote measurement, and also has an oscilloscope function built-in, which facilitates operators in carrying out operations, testing, and calibration work.
  The built-in frequency test function of the ST100 series time-frequency synthesizer test instrument can test the stability and accuracy of the measured input signal using an external clock signal or the built-in Rubidium clock/Crystal oscillator as a reference.
Product features

Supports combined time and clock testing, meeting the requirements of different testing environments

Remote connection test software can be installed on a variety of operating systems

Supports manual, automatic, and timed testing methods

Supports NTP, PTP response capability testing

Handheld terminal, 10-inch touch screen LCD local display and control, easy to operate, three steps to reach

Supports statistical analysis such as RMS, standard deviation, etc.

Product Features

Specification name

Indicator parameters

Remarkss

Reference Source

External References

Can receive BeiDou(COMPASS)/GPS satellite time

1PPS+TOD

IRIG-B code and other time references

External frequency source (10MHz/5MHz)


Built-in reference

High stability rubidium clock, supports external 10MHz (10 seconds) taming and second taming


Taming Precision

Better than 3E-11 (15 minutes)

Better than 1E-12 (60 minutes)


Frequency stability test

Measuring range

5M~200MHz

Frequency stability test is an optional function that supports 2-channel simultaneous testing

Precision test accuracy

5E-13

Stability test accuracy

1E-12/1s

5E-13/10s

1E-13/100

Time code measurement

Measurement Type

Support 1PPS/1PPX, 1PPS+TOD, IRIG-B (AC), IRIG-B (DC), serial time message, DCF77, DCLS and other time codes, pulse tests

Supports optical B code and optical pulse signals

Support 3-channel pulse measurement, IRIG-B (AC) test is optional1

Test resolution

45ps

Clock Measurement and Analysis

Measurement Type

Support G.703 2.048MHz/2.048Mb/s, SyncE clock analysis ;

E1 jitter test (send/receive), drift transmission, bit error test (measurement/insertion) ;

Supports clock TIE, MTIE, TDEV\ADEV measurement and calculation, and template comparison and in-depth analysis according to G.811, G.812, G.813, G.823, G.8261, etc.;


Network Measurement

Measurement Type

Support NTP (SNTP, v2, v3, v4) and PTP (1588v2) network time interface. The network interface can be flexibly configured in master-slave mode, suitable for the construction of various test models;

Support 10G, 1000M, 100M, 10M network environment;

Support PDV/IPDV testing, which can count, analyze and save timestamp data in real time, facilitating quick fault location and abnormal analysis;

Support NTP and PTP response capability testing, time stamping and packet capture for any network message;

10G is optional1

High-precision measurement

Test functionality

Optional high-precision single-point positioning remote test, with accuracy better than 1ns;

Optional high-precision BeiDou(COMPASS)/GPS satellite common view remote test, with accuracy better than 5ns;

Optional high-precision optical fiber bidirectional comparison test, with test uncertainty better than 200ps;

You can choose to conduct industry tests such as mobile OAM, interconnection and consistency;

Optional power time synchronization industry test;

Optional rubidium clock, crystal oscillator testing and calibration;

All optional

Simple Oscilloscope

Test functionality

Supports waveform testing such as pulse amplitude, duty cycle, and period;

Support trigger sampling and automatic measurement functions;


Reference signal output

Output Type

Support 1PPS/1PPX, 1PPS+TOD, IRIG-B (AC), IRIG-B (DC), serial/network time message, DCF77, NTP/SNTP, PTP (1588v2) DCLS, 5/10MHz, SyncE, 2.048MHz/2.048Mb/s and other time and frequency signals;

IRIG-B (AC) output bit option 1

Time code deviation

±500ms, resolution 0.1ns

Frequency signal

The default output frequency is 10MHz, and the output frequency can be set to any frequency from 1MHz to 300MHz.

Power consumption

Power supply

Power adapter voltage: 220VAC±10% 50Hz

Charging voltage: 19VDC (Vcc±5%)

Current

< 2A (fully charged) < 4A (charging)

Battery

Built-in lithium-ion rechargeable battery, battery life 2-4 hours

Power interface

3.5mm round socket

Ambient temperature

Operating temperature

-20ºC ~ +50ºC

Storage temperature

-40ºC ~ +70ºC

Weight and Size

Weight

<3kg

Size

316*251*88mm